New keypad interface and PC software
Supports: English, Chinese and Italian Languages
LCD panel, friendly human-machine interface easier
for commissioning and diagnostic.
Support parameter upload & download and remote control
Power Configuration |
|
790P Four Quadrant Regenerative; 2 Fully Controlled Three Phase Thyristor Bridges |
|
791P Two Quadrant Non-Regenerative ; 1 Fully Controlled Three Phase Thyristor Bridges | |
Thyristor Controlled Variable Field Supply |
|
Armature Current Ratings(Adc) |
Frame
1:40A, 80A, 110A, 150A |
Overload |
150% for 30 seconds |
Armature Voltage |
V armature=Vac x 1.15 |
AC Supply Voltage (Vac)45~62Hz |
Sinusoidal three phase 220-500V or 690V (±10%) |
Field Current |
Maximum Field current for each frame size: 10~64a (see table) |
Field Voltage |
V field=Vac x 0.82 |
Ambient |
Between 0 and 40C for maximum performance Between 40 and 50C with 4% downgrade |
Storage Temperature |
-7.6℉ ~ 131℉ |
Altitude |
Derate 1% per 100m above 1000m |
Protection |
High Energy MOVs; Heat sink Over temperature |
Instantaneous Over current |
|
Inverse Time Over current; Interline Snubber Network |
|
Field Failure Zero Speed Detection |
|
Speed Feedback Failure |
|
Inputs/Outputs
|
8 digital inputs (optically isolated, fully programmable) |
6 digital outputs (optically isolated, fully programmable) |
|
4 analog inputs, fully programmable (AIN1 and AIN2 can be configured as differential input) |
|
2 analog outputs (fully programmable) |
|
2 encoder inputs for feedback and reference(optically isolated),line driver and single ended built in |
|
2 tachometer feedback inputs |
|
armature voltage feedback with I*R compensation |
|
status LED's for all inputs and outputs |
|
Reference Supplies |
+5V dc (encoder) +10V dc (potentiometer) +24V dc (encoder and digital I/O) |
Supported interfaces |
Built-in RS232 connector for interfacing with PC |
Built-in RS485 for creating a drive network |
|
Built-in 2 Canbus interface, support standard Can-open communication ability for creating point-to-point communication network and master-slave communication. Support Fieldbus communication : Profibus, Device-net, Can-open, CC-Link, Modbus-RTU, Ethernet, etc. |
▲To zoom in, right click to save the picture.