AC Drives
  • ac7801
  • ac780
  • ee01
  • ee02
  • ee03
  • 780__1
  • 780__2
  • 780__3
  • 780__4
  • 780__5
  • ac7801
  • ac780
  • ee01
  • ee02
  • ee03
  • 780__1
  • 780__2
  • 780__3
  • 780__4
  • 780__5
  • ac7801
  • ac780
  • ee01
  • ee02
  • ee03
  • 780__1
  • 780__2
  • 780__3
  • 780__4
  • 780__5
AC780 - General Purpose AC Drive
AC Drives
200V(1P/3P): 0.4kW~2.2kW
400V(3P): 0.75kW~355kW
AC780 uses the most advanced vector control strategy. V/F control and high performance sensorless vector control. LED/LCD operator panel.
AC780 - General Purpose AC DriveAC Drives
  • Features
  • Technical Specification
  • Nameplate
  • Sizes
  • Cases
  • Troubleshooting
  • Download

Features

  • VF control / high performance sensorless vector control
  • High start torque: 0.5Hz/150%(SVC)
  • High steady-state precision: +-0.5%(SVC)
  • speed ratio: 1:200(SVC)
  • Various fieldbus support: MODBUS, Canbus, Profibus, Canopen, DeviceNet, Modbus/TCP, EtherNetIP;
  • Self-tuning and auto slip and torque compensation;
  • Various Built-in function blocks: multi-speed, simple-PLC, S curve, multi-function digital input and outputs, multi-function analog input and output(can be configured to either 0~20mA or 0~10V ), over current and over voltage protection, LVRT, DC brake, Aux-PID, constant pressure water supply, high frequency pulse input and output. Etc
  • Reliable OV, UV, OC, OT, SC,GND protections


\
\



Excellent motor control performance

l  VF control、high performance sensorless vector control

l  High start torque: 0.5Hz/150%(SVC)

l  High steady-state precision: +-0.5%(SVC)

speed ratio: 1:200(SVC)

l  Torque control precision: +-5% rated torque

Powerful fieldbus network support

l  Built-in RS485 serial communication(standard MODBUS-RTU)

l  Various fieldbus support: MODBUS, Canbus, Profibus, Canopen, DeviceNet, Modbus/TCP, EtherNetIP;

Flexible expansion capability

l  Various fieldbus expansion cards;

l  Analog input and output expansion;

l  Digital input and output expansion;

l  Remote control panel and LCD panel

Perfect protection and high reliability

l  Over current and over voltage protection under all operation conditions;

l  Perfect overload, short circuit, grounding, over temperature protection;

l  Cycle by cycle trip functionality, highly improve the drive reliability;

l  Perfect torque response performance;

l  150% overload test and 48h aging test;

Widely used application fields

l  Various common DC bus applications;

l  Wire draw machine separate motor control;

l  Torque control;

l  Crane machine and lifting;

l  Plastics, rubber and extruders;


Technical Specification

ETD AC780 Specifications

Input

Rated voltage frequency Allowable fluctuation

200V/50Hz/60Hz, voltage: +-10%, Frequency: +-5%

400V/50Hz/60Hz, voltage: +-10%, Frequency: +-5%

480V/50Hz/60Hz, voltage: +-10%, Frequency: +-5%

Output

Rated voltage

3 phase: 200V(proportional to the input voltage)

3 phase: 400V(proportional to the input voltage)

3 phase: 480V(proportional to the input voltage)

Voltage/Frequency

Running command channel

Operator panel, control terminals, communications, and can switch by different ways,

Frequency reference channel

Digital, analog, communication, AUX-frequency, can switch over between these sources.

Speed range

1200(open-loop vector)

Start torque

0Hz 150 rated torque(open loop vector)

Output frequency

0Hz400Hz

Frequency resolution

Digital command: ±0.01%; analog command: maximum frequency× 0.2%Hz

Running speed steady-state accuracy

≤±0.5rated sync speed(open loop vector)

Torque boost

Automatically or manually

Control mode

Open-loop vector, close-loop vector, open VF, close VF, AFE

Control Functions    

Speed up/down curve

Line speed up/down, s-curve speed up/down; 4 speed up/down times, time unit(hour or minute), max 60 hours

Automatic voltage regulator(AVR)

Overload, over current, over voltage, short-circuit, speed loss, over temperature etc.

V/F Curve

Line, 2nd power and 3rd power Volts/Hz curve

Analog

Built-in 2 analog inputs and two analog outputs channels; each can be configured to0~10V or 0-20mA (or 4-20mA) analog input and 0~10V or 0-20mA (or4-20mA) analog output channels.

Brake torque

20%(without resistor), 125% with braking resistor

LVRT

Continues running when sudden power loss

Ramp block

Ramp ACC/DEC auto blocked when current or voltage limited

Multi-function input

Include 5 digital input terminals (S1~S5), can achieve: drive enable, speed enable, differential input enable, analog input enable, jog enable, torque enable, AUX-PID enable, motor-driven potentiometer, 2 motor parameters option, external fault etc.

Multi-function output

Include 4 digital output terminals (Y1~Y4), can achieve: drive ok, fault indication, running indication, frequency detection, minimum speed indication, drive overload, speed up/down finish, overcurrent indication, internal comparator output etc.

Protections

Overload, over current, over voltage, short-circuit, speed loss, over temperature etc.

Overload

G type: 150% rated load for 1min

P type: 120% rated load for 1 min

Instantaneous Over current

G type: 250% rated current

P type: 200% rated current

Over temperature

Internal electronic circuitry protection

communications

Built-in RS485 serial communication(standard MODBUS-RTU)

Various fieldbus support: MODBUS, Canbus, Profibus, Canopen, DeviceNet, Modbus/TCP, EtherNetIP;

Environment

Ambient temperature

14℉ ~ 104℉ (de-rated when used in 104122)

Humidity

5% ~ 95RH, no dew and no hydrosphere

Vibration

Less than5.9m/s2  (0.6g)

Storage temperature

-40℉ ~ 158

\

▲To zoom in, right click to save the picture.


Nameplate



Sizes


Model

W

W1

H

H1

B

D

1/3 phase 200V class

780G/0000.4/200

105

95

150

139

132

M4

780G/0000.75/200

780G/0001.5/200

105

95

190

179

144

M4

780G/0002.2/200

3 phase 400V class

780G/0000.75/400

105

95

150

139

132

M4

780G/0001.5/400

780G/0002.2/400

105

95

190

179

144

M4

780G/0003.7/400

780G/0004.0/400

780G/0005.5/400

123

95

350

334

230

M5

780G/0007.5/400

780G/00011.0/400

165

108

453

436

258

M6

780G/0015.0/400

Model

W

W1

H

H1

B

D

3 phase 400V class

780G/0018.5/400

180

120

480

463

324

M8

780G/0022.0/400

780G/0030.0/400

180

120

560

543

324

M8

780G/0037.0/400

780G/0045.0/400

273

185

732

702

365

M8

780G/0055.0/400

780G/0075.0/400

273

185

732

702

365

M8

780G/0090.0/400

780G/0110.0/400

375

274

884

846

415

M10

780G/0132.0/400

780G/0160.0/400

541

405

986

951

425

M10

780G/0185.0/400

780G/0220.0/400

780G/0250.0/400

730

502

1231

1190

502

M10

780G/0280.0/400

780G/0315.0/400

780G/0355.0/400

3 phase 480V class

780G/0005.5/480

123

95

350

334

230

M5

780G/0007.5/480

780G/00011.0/480

165

108

453

436

258

M6

780G/0015.0/480

780G/0018.5/480

180

120

480

463

324

M8

780G/0022.0/480

780G/0030.0/480

180

120

560

543

324

M8

780G/0037.0/480

780G/0045.0/480

273

185

732

702

365

M8

780G/0055.0/480

780G/0075.0/480

273

185

732

702

365

M8

780G/0090.0/480

Model

W

W1

H

H1

B

D

3 phase 480V class

780G/0110.0/480

375

274

884

846

415

M10

780G/0132.0/480

780G/0160.0/480

541

405

986

951

425

M10

780G/0185.0/480

780G/0220.0/480

780G/0250.0/480

730

502

1231

1190

502

M10

780G/0280.0/480

780G/0315.0/480

780G/0355.0/480



Cases

Troubleshooting

Download

  • ETD AC780 Brochure
  • Wiring Diagram DC790P+AC780+AC800+AC800CM